Notifier: fire detection and alarm
Panels, field devices and system integration, supplied and supported by Mat Incêndio engineering.
A platform for detection, operation and maintenance
Modular panels with a 10-inch touchscreen, self-test detectors and CLSS connectivity, depending on the devices and licences specified for the project.
N16E
1 to 3 loops, up to 954 points.
N16X
Expansion to 10 loops, up to 3,180 points.
Operation and integration
NOTI-FIRE-NET networking with up to 200 nodes, integration with addressable VESDA devices and BACnet IP and Modbus IP communication options.
CLSS and self-test
Monitoring, diagnostics and maintenance reports using compatible services and equipment.
Capacity and features depend on configuration and licensing. Engineering specifies the equipment and checks compatibility for each installation.
Explore the INSPIRE platform (PDF) →
ONYX series and conventional panels
Panel selection considers installation size, detection architecture and fire suppression control requirements.
ONYX · NFS-320
1 addressable device loop.
ONYX · NFS2-640
1 to 2 loops.
ONYX · NFS2-3030
1 to 10 loops.
SFP series · conventional
Zone-based detection panels with notification circuits.
RP-2002(e)
6 zones, for detection and suppression agent release applications.
Detection, activation and notification
Detectors, manual call points, modules and notification appliances are selected for the application and panel compatibility.
Detectors
Photoelectric smoke · FSP-951 series
Temperature · FST-951 series
Multicriteria detection, OSID beam detection and VESDA aspirating detection.
Manual call points
Addressable NBG-12LXP and conventional models; specific options for agent release.
Interface modules
Control and monitoring, loop isolation and suppression applications, including FCM-1-REL.
Notification and power
Audible, visual and audiovisual appliances; mounting bases and auxiliary power supplies.
VESDA: aspirating smoke detection
Air sampling through a pipe network for early smoke detection. Detector and sampling point selection considers the environment and project requirements.
Applications presented in the technical material include data centres, warehouses, airports, hospitals and industrial facilities.
VEP, VES and VEA families offer different sampling and event identification configurations.
View the VESDA presentation (PDF) →
Off-gas detection for lithium-ion batteries
Li-ion Tamer GEN 3 monitors gases released by lithium-ion batteries. Application is determined by the energy storage system architecture.
See the presentation supplied by Honeywell for the concept, components and application criteria.
View the Li-ion Tamer presentation (PDF) →From the panel to operational monitoring
Communication between panels, annunciators and supervisory systems, sized for the installation.
NOTI-FIRE-NET
Communication network linking compatible panels and devices.
Supervision and building integration
Interfaces for building systems, annunciators and graphical workstations, depending on the installed platform.
ONYX and INSPIRE retrofit
The project checks firmware, annunciators and existing interfaces before integration. Compatibility between all generations is not assumed.